Internal wall insulation thickness on a Scottish stone wall, with the systems we fit, comes to roughly 105 to 125mm from bare stone to the new finished face, about four to five inches. On many walls your room gives up less than that, because the old plaster comes off before anything new goes on. Plan the furniture around 120mm on each insulated wall and let the survey tape measure refine it.
- Our vapour-open build-up for sandstone measures roughly 115 to 125mm from bare stone to finished plaster, so plan on 120mm for each insulated wall.
- The fixed layers come to 105mm: two 50mm hemp layers compressed to 90mm in a timber frame, plus a 15mm wood wool board.
- In a 4m by 3.5m bedroom with one external wall, 120mm of build-up takes 0.48 square metres, about 3.4% of the floor.
- Stripping the old lath and plaster back to stone gives some depth back, so the net loss on a wall is often less than the build-up.
- On absorbent sandstone a thin foil-faced board risks trapping moisture, and extra thickness beyond the checked build-up leaves the stone colder and more exposed to frost.
- Bay windows in Glasgow’s sandstone tenements lose the most depth, because every pier and splayed side takes its own layer of insulation.
The figures on retailer pages, 50mm here and 25mm there, usually describe foil-faced boards fixed to a modern wall. A pre-1919 stone wall sets its own depth, because the build-up has to manage moisture as well as heat. That depth is worth knowing in millimetres before you plan a single room.
Internal wall insulation thickness, layer by layer
A plasterer working the finish coat beside a window, and a hemp batt pressed into its timber frame.
These figures come from the vapour-open system we fit on absorbent sandstone. Our build-ups for Scottish stone walls come from a library of assemblies checked in WUFI, software that models how heat and moisture move through a wall. Working out from the stone, the layers run like this:
- Bare stone. The old lining comes off first, right back to the stone.
- Lime parge coat. It fills the voids in the stone face and flattens it. It is thin over the high points and deeper in the hollows. Lime suppliers’ own guidance for levelling uneven stone runs to around 10mm, and more in a bad hollow.
- Hemp in a timber frame. Two 50mm layers of IndiTherm hemp, compressed to 90mm inside a 45mm treated timber frame.
- Wood wool board. A 15mm board, the rigid layer the plaster grips.
- Lime plaster and paint. Two coats of lime plaster with an embedded mesh, around 8 to 10mm in total, the thickness lime manufacturers’ guides give for wood wool board. Then a vapour-permeable paint or limewash, which adds no measurable depth but has to be the right product. We give guidance on which one to use.
layers of IndiTherm hemp, compressed into a 45mm timber frame
wood wool board over the frame, ready for two coats of lime plaster
Source: the vapour-open build-up Insulation Installers Scotland fits on sandstone.
Add the fixed layers and you have 105mm before a trowel touches the wall. With the parge and the plaster, the finished face lands roughly 115 to 125mm in front of the high points of the bare stone, between four and a half and five inches.
There is no air gap anywhere in that depth, by design. The parge closes the hollows and the compression keeps the hemp tight in its frame, so there is no pocket of cold air for moisture to condense in.
Measured from the stone, or from the wall you have now?
An outside wall stripped back to bare masonry around the window, with the old lining gone.
Before any of those layers goes on, the existing lining comes off. We strip every external wall we insulate back to bare stone. Wallpaper, plaster and any lath-and-plaster lining fixed to timber straps all go.
That lining has depth of its own. In a sandstone tenement the plaster often sits on lath over straps, with a gap of an inch or two between it and the stone. So several centimetres come back to the room once the strip-out is done. Plaster laid straight onto the stone gives back less.
The net loss on any one wall is the build-up minus whatever the strip-out removed. That is why two walls in the same flat can lose different amounts. Our guide to how a tenement flat’s walls are built and insulated sets out the layers, straps and all.
For a planning figure that should not catch you out, allow 120mm per insulated wall and expect the tape measure to show less on a strapped and lathed wall. The survey confirms the real figure wall by wall.
Every layer here ends up behind lime plaster, so ask at your survey about the photographs you get of the work before it is covered.
Book Your Free Survey →“Post work photo evidence was supplied of all the insulation work which is great as well.”
Maarten Hofland
Google review
What 120mm means in square metres
A plastered room after insulation, with deep reveals round the glazed door and the window.
Floor area is where the number turns into something you can picture.
- One external wall. A 4.0m by 3.5m bedroom (14 square metres) with its 4m side insulated at 120mm loses 0.48 square metres, about 3.4% of the floor. That is a strip roughly the width of a paperback along the wall.
- A corner room. The same room with external walls on its 4m side and its 3.5m side loses about 0.89 square metres, roughly 6.3%, leaving a room of around 3.88m by 3.38m.
Walls between rooms, and walls shared with the flat next door, stay as they are. When people search for insulating internal walls, they usually mean lining the inside face of the external walls, and that is the whole job. The partitions keep every millimetre.
On an open wall the percentages barely register. The pinch comes at fixed points.
- A 600mm gap for a fridge or washing machine that ends at an external wall becomes about 480mm.
- A double bed that fitted wall to wall across a narrow room loses its clearance.
- Built-in wardrobes on an external wall come out for the strip-out anyway, and go back either shallower or further into the room.
Internal wall insulation thickness on the vapour-closed route
An airtight membrane taped round a pair of windows and their reveals, before the plasterboard goes on.
Some solid walls in Scotland are low-absorption brick, or brick that sits behind an external render. Little moisture gets into those walls from outside, and what gets in from the room struggles to dry outwards. So the job on those walls is to keep warm, moist room air away from the wall in the first place.
Our internal solid wall insulation build-up for that wall is slimmer:
- the same hemp on a 45mm timber frame
- a Pro Clima Intello Plus membrane (an airtight sheet that controls water vapour), with Tescon Vana tape on the joins and Contega Solido tape round the edges
- 12.5mm plasterboard with a multifinish skim
With no parge coat and no lime coats, the finished face typically comes out at around 105mm: the hemp at the same 90mm as the sandstone build-up, plus the board and a skim of a few millimetres. The survey confirms the exact figure for your wall.
This route also allows thinner insulants where a room cannot spare the depth. PIR (rigid plastic foam board) and aerogel are among the alternatives we can fit on these walls, chosen to hit a heat-loss target within the space available.
Your survey settles which kind of wall you have, and the thickness on each wall follows from that.
Book Your Free Survey →“Although the quote that Calum provided was higher than the quote from another, Calum went out of his way to spend time walking me through the pros and cons of different insulation/plaster types for older properties, and I decided to give him my business.”
Ricky Munday
Top-floor tenement flat, conservation area · Google review
Why we will not go thinner, or thicker, on sandstone
Wood wool board fixed with washer discs across a whole room, the layer the lime plaster grips.
The obvious question is whether a 50mm board would do the job in half the depth. On absorbent sandstone, the thin boards that come close are foil-faced and vapour-closed, so water vapour stops dead at them.
A sandstone wall soaks up driving rain and relies on drying out afterwards. With a sealed board in the way, moisture that soaks in from outside stays in the wall, out of sight, until timber in or against the stone starts to rot.
It costs more depth, and in return the wall keeps moving moisture through and drying out.
The reasoning is set out in why a thin foil-faced board is the wrong swap on sandstone.
Thicker is no better. Calum Farquhar, who owns the company and leads our system design, puts it plainly: too much insulation on a sandstone wall makes the stone itself run colder through the winter. Rain still soaks into the outer face, and a colder, wetter stone goes through more freeze-thaw cycles. Freeze-thaw is the process that cracks sandstone and breaks down lime mortar.
The 90mm hemp layer is the depth in the build-ups our WUFI library has checked for these walls, modelled for heat and moisture together. So we hold to these millimetres. If a room cannot spare 120mm on one wall, the answer is a different detail on that wall, agreed at survey, and the wall still has to be able to dry.
Bay windows and window reveals
A bay lined with insulation in a timber frame, round the reveals and below the sills.
The bay is where room loss shows most. A canted bay in a red or blonde sandstone tenement, the kind found across Hyndland and Strathbungo, is several short lengths of stone wall: the splayed sides, the narrow piers between the windows and the stone below each window board. Each one takes the build-up where it fits.
The bay gives up that depth at its back. Because the splayed sides run at an angle, it also narrows between them by more than twice the build-up, so allow more than 240mm at our planning figure. If a dining table lives in your bay, measure it against the smaller bay before you commit.
Windows stay where they are in the stone. Everything on the room side comes forward, so each reveal gets deeper by the build-up, and new, deeper window boards go in once the plaster has dried. Contega Solido airtightness tape goes round every window perimeter, sealed to the wall, before the hemp and frame go up.
The reveals themselves need insulating. Leave the sides of an opening bare and heat escapes through the strip around the window, which is where cold spots and mould tend to gather on an insulated wall.
- Where a reveal has room, it takes the full system.
- Where the lining would start to cover the window frame, a thinner detail goes on. On the vapour-closed route that can be EPS or XPS (polystyrene boards) or aerogel board. On sandstone we keep several thinner reveal designs for tight openings.
- Which one suits a particular sash-and-case window is a survey decision.
Working timber shutters are joinery fixed against the old lining. On an insulated wall they have to be adapted or remade to suit the deeper reveal, and the quote includes that joinery time.
Bring the bay, the shutters and the awkward wardrobe alcove to the survey, so the joinery, the reveals and the insulation are planned as one job.
Book Your Free Survey →“Calum was very patient with us while we deliberated on materials. We had some fairly specific requirements which were all accommodated without fuss.”
Jamie B
Google review
Skirtings, sockets, radiators and the cornice
New plaster on the window wall, with the side wall still in its old finish.
The order of work explains what happens to each fixture.
- Radiators and sockets come off. We disconnect and remove them before anything else.
- The wall is stripped to stone. The lath and plaster come off, and the cornice and any decorative panelling on those walls go with them.
- The build-up goes on, finishing with lime plaster, which can take weeks to dry fully.
- Skirtings and window boards go on once the plaster is fully dry.
- Radiators and sockets go back after plastering or after painting, whichever you prefer.
Each radiator now hangs roughly the depth of the build-up further into the room, so its pipe connections have to reach the new wall face. Each socket sits in the new surface.
Then there is the cornice. A cornice along an external wall cannot stay in place while the wall behind it is stripped to stone and rebuilt more than 100mm further forward, and original cornice or panelling rarely survives that change. The profile is recreated in lime once the insulation is in, and at the survey we agree exactly who does that work. The internal walls sit outside the strip-out, so the new runs are matched to the cornice on those walls where they meet in a corner.
Planning it room by room
A bedroom cleared back from its walls, with the remaining furniture under dust sheets.
Room loss is uneven across a home, which is why it pays to plan it one room at a time. An internal hall or box room with no external wall loses nothing at all. A room with one external wall loses a strip along it. Corner rooms and bay-windowed front rooms lose the most, and in a tenement flat the bay-windowed front room tends to be the best room in the house.
Kitchens and bathrooms need the most thought. Units, worktops, tiling or a basin on an external wall all come off for the strip-out. The best time to insulate those walls is when the room is being refitted anyway, with the new kitchen drawn around the new wall line. Calum puts the share of heritage jobs that start during a refurbishment or soon after a move at around 30%, and those are the easiest jobs to plan around.
The system can also go in one room at a time, so the bedrooms can go first and the kitchen can wait for its refit.
- Cost: heritage vapour-open internal wall insulation runs £10,000 to £50,000. The jobs we win typically land between £14,000 and £25,000, and cornice, reveals and bays move the price as much as wall area does.
- Payment: no deposit, and payment terms of 7 days.
- Grant: if you are eligible, Home Energy Scotland pays up to 75% of the combined cost, capped at £7,500 per property, and solid wall insulation has its own cap of the same £7,500. An optional interest-free loan, capped at £2,500 for solid wall insulation, can sit alongside it.
- Installer: the work must be done by a TrustMark-registered installer, which we are, alongside our PAS 2030 accreditation. Home Energy Scotland assesses every application and decides what it will fund.
You can see what a whole-flat job costs before and after the grant, band by band. We checked the grant figures against homeenergyscotland.org on 25 September 2026.
The service page covers the full heritage wall system we fit, including the 25-year workmanship guarantee that comes with it.
Ask at survey how the rest of the house is protected while one room is stripped back to stone.
Frequently asked questions
At the window reveal you can see how much depth the insulation adds to the wall.
How thick is internal wall insulation?
Roughly 105 to 125mm on a Scottish stone wall with the systems we fit. The heritage vapour-open build-up has 105mm of fixed layers, 90mm of compressed hemp and 15mm of wood wool board, plus a lime parge and two coats of lime plaster. The vapour-closed build-up for low-absorption or rendered brick typically comes out at around 105mm.
Does internal wall insulation make rooms smaller?
Yes, by the build-up depth, less the old lining removed first, on each external wall that gets insulated. In a 4m by 3.5m room with one external wall, 120mm costs 0.48 square metres, about 3.4% of the floor. Partition walls are left alone, so a room with no external wall keeps every millimetre.
Is 50mm insulation enough for walls?
Not on absorbent sandstone, where the thin boards that fit into 50mm are foil-faced and vapour-closed and can trap moisture in the stone. Our heritage build-up uses 90mm of hemp. Going thicker than that checked build-up is no answer either, because it leaves the stone colder and more exposed to frost damage.
Does internal wall insulation need an air gap?
Our vapour-open build-up has no air gap, on purpose. A lime parge coat fills the voids in the stone face, and the hemp is compressed into its frame, so no cold pocket exists for moisture to condense in. Old lath-and-plaster linings often had a gap behind them. The new build-up is solid, vapour-open layers from stone to plaster.
Can you insulate a bay window from the inside?
Yes. Every stone surface in the bay takes the build-up where it fits, and each reveal gets the full system or, where the window frame leaves little room, a thinner reveal detail chosen at survey. The bay ends up narrower by at least twice the build-up, so measure any furniture that lives there.
Do radiators and sockets have to move?
They come off and go back on the new wall face. We disconnect and remove them before stripping the wall, then reinstate them after plastering or after painting, whichever you prefer. Each radiator sits roughly the build-up depth further into the room, with its pipe connections extended to reach.
What happens to cornicing during internal wall insulation?
Cornice on an external wall is removed and recreated. It cannot stay in place while the wall behind it is stripped to stone and rebuilt further forward, and original cornice rarely survives that change. The profile is recreated in lime once the insulation is in, with the new runs matched to the cornice on the internal walls, which sit outside the strip-out. At the survey we agree exactly who does that work.
If your question is about one particular wall, a free survey answers it with a tape measure in your own rooms.
Book Your Free Survey →“Calum did a great job to design a solution that fitted my needs. It’s been 5 months and I cannot understate how much their insulation improved the comfort and efficiency of my flat.”
Oliver Dillon
Flat · Google review
Get your own walls measured
A figure in a blog gets you as far as the furniture plan. Your own number depends on what sits on each wall now, how uneven the stone is behind it, where the windows sit in their reveals, and whether the wall is sandstone that needs the vapour-open system or brick that suits the slimmer route.
A free survey measures all of that. It comes back as a written quote that confirms the depth each wall will lose, the detail for each reveal and what the Home Energy Scotland grant could cover.
Or call us on 0141 465 5812