Underfloor Insulation in Partick: Warmer Ground-Floor and Main-Door Flats
Warmer boards in a ground-floor or main-door flat, usually after a single fitting day, and up to £1,500 from Home Energy Scotland if you qualify.
Underfloor insulation
-
The cold void
-
Wool between the joists
-
Netting underneath
-
A warmer floor
Illustration: underfloor insulation, step by step
-
The cold void
-
Wool between the joists
-
Netting underneath
-
A warmer floor
Why the Floor of a Partick Ground-Floor Flat Stays Cold
The radiators are hot, yet your feet are cold and you can feel air moving at the skirting boards.
Underfloor insulation in Partick deals with it from below, where the cold gets in.
-
Under a ground-floor flat in an older Partick tenement there is usually a gap between the floorboards and the bare earth, which Scottish builders call the solum.
-
Small vents at the foot of the front and back walls, known as air bricks, carry air through the gap so the timber joists under your boards stay dry.
-
That air comes in from the street and the back court at outdoor temperature, and nothing stops it chilling the boards above.
-
Air still has to move beneath the insulation, and as long as it does, the floor stays dry.
-
Our crew packs mineral wool between the joists on a netting support, the same underfloor insulation we fit across Glasgow, and keeps every air brick clear.
Two kinds of flat have nothing for us to fill. Higher up the close, the space below your boards is the ceiling of the flat underneath.
Newer blocks usually sit on concrete.
Finding no air bricks along the foot of the walls is one quick way of checking whether your floor is suspended timber or solid.
A Home Energy Scotland grant can pay part of the cost if your household qualifies. There’s always a share left for you, and the quote spells out both figures.
What we actually do
Two ways to insulate your floor, and what each one involves.
There are two ways to insulate a wooden floor with a gap underneath (a suspended timber floor), and the prices are far apart. Here is how each one is done.
From survey to aftercare
Our Process for a Partick Floor, Survey to Fitting Day
-
Step 1
Survey Visit
Calum or Lewis, our surveyor, measures the space below your boards and checks the joists and the air bricks. You get the quote in writing, and nothing is booked until you say yes.
Survey first Before we recommend either job, we check how your floor is built, the space underneath it and the vents that keep that space dry. -
Step 2: the split
One of two ways, picked for your floor
-
The standard job
We fit Knauf Omnifit 40 insulation between the joists (the timber beams under your floorboards), support it so it can’t sag, and seal the gaps where draughts get in. You get a much warmer floor for roughly half the cost of the airtight job.
-
The airtight job
We lift the floor and rebuild it with hemp insulation between the joists. A membrane on the room side keeps moist indoor air out of the space under the floor, and a second membrane underneath lets damp escape. We tape every joint to stop air leaking through. It gives the best result where your floor allows it.
-
-
Step 3
Fitting Day
The crew fits Knauf Omnifit 40 mineral wool on netting between the joists, from a hatch where there is one. One day covers a standard floor, with the mess cleared before the crew goes.
Air bricks kept clear We keep the air bricks (the small vents low in your outside walls) clear, so air keeps moving under the floor and the timber stays dry.Boards lifted and re-laid If we can’t get under the floor on a standard job, we lift your floorboards and put them back afterwards, taking extra care with old boards. -
Step 4
Photos, Paperwork and Guarantee
Home Energy Scotland gets the installer paperwork it asks for. The photos and your 25-year workmanship guarantee come to you, ready to file with your property papers.
Grant funding and EPC We help with your Home Energy Scotland grant if you qualify, answer your questions about it, and provide a new EPC after the work where you need one. -
The honest bit: which level your floor needs
The standard job suits most of the floors we see. The airtight job costs more, because we rebuild the whole floor with two membranes and taped joints, and the natural insulation costs more too. We will tell you which one your floor and budget call for, and the choice is yours.
How each system goes in
Underfloor Insulation Fitted Below Your Partick Floorboards
Each card below shows one system building up layer by layer, the way we fit it. The pictures are illustrations.
Illustration: standard system
-
The cold void
Each line of light is a gap between your floorboards. Cold air from the air bricks comes up through those gaps and in at the skirtings, into the room you pay to heat.
-
Wool between the joists
We reach the void through one small hatch, and most floors take a day. Knauf Omnifit mineral wool, cut a touch wider than the space between joists, grips them and fills their full depth.
-
Netting underneath
Support netting fixed under the joists holds the wool up, so it can't sag over the years. We photograph it all for you, since you won't be crawling under there to look.
-
A warmer floor
On the first cold Partick night after we've been, the boards under your socks feel warmer than they did last winter. Up in the room, the draught at the skirtings eases off and less heat escapes through the floor.
Standard underfloor insulation with Knauf Omnifit
When there is room to work in the void below, we fit it from underneath, so your floorboards stay down and the job is usually done in a day.
Our most popular option and superb value when there is access from below. We work in subfloor spaces as shallow as 350mm, fitting 150 to 200mm Knauf Omnifit 40 rolls friction-cut to fill the full joist depth, lagging the heating pipes and fixing insulation support netting underneath so it never sags. Ventilation is kept clear, airbricks are extended where needed, and every access hatch is insulated and screwed back down. A breathable membrane and airtightness tape can be added for extra performance.
Illustration: hemp system
-
Boards up, one room at a time
We lift the floorboards to open up the joists.
-
A hammock between the joists
A thin sheet is slung between the joists and taped round its edges.
-
Hemp cut to fit
IndiTherm hemp is cut to sit snugly in each hammock.
-
Sealed, then boarded
A taped top sheet goes over the joists, then your boards go back down.
Hemp underfloor insulation with airtightness membranes
Hemp suits you if you want a natural, Scottish-made material and the best airtightness, and you are happy for the boards to come up room by room. It costs more than the standard job because the floor is lifted and every join is taped.
For a natural, higher-end floor we fit IndiTherm hemp, made in Scotland by IndiNature, working room by room. We sling a thin sheet between the joists like a hammock, tape it round the edges and cut the hemp to fit snugly inside it. A second sheet goes over the joists, taped down to keep moist room air out of the floor, before the boards go back. Installed from above it gives the highest performance with no compromise on airtightness.
Illustration: PIR board system
-
Battens at your heating level
25mm treated battens are fixed to the joists at your heating design level.
-
Foil-faced board between the joists
PIR is cut tightly to fit between the joists and rests on the battens.
-
Foam edges, taped joins
Foam seals the perimeter and foil tape covers every join.
-
Heating on top
The pipes go in above the board. Then the floor goes back on top.
PIR insulation for underfloor heating
Underfloor heating laid over a cold, ventilated void loses heat downward unless there is insulation beneath it. A foil-faced foam board (PIR) under the heating sends that warmth back up into the room, where you want it.
We recommend high-performance foil-faced PIR, fitted on 25mm treated battens set to your heating design level and cut tightly between the joists, with airtightness foam sealing the perimeter and foil tape over every join. Most underfloor heating contractors do not hold the TrustMark certification for underfloor insulation, so we carry out this element, which keeps up to £1,500 of Home Energy Scotland grant open to you if you qualify. We are happy to work alongside your contractor or recommend a trusted partner.
Why Partick Owners Pick Us as Their Underfloor Insulation Installers
-
A straight answer by phone for upper floors
Tell us which floor your flat is on. If there’s no gap under your boards, we say so straight away and nobody books a visit.
-
Carpets up after a move? Call before the new ones go down
If the crew has to lift boards, bare boards are simpler to work with than a new carpet rolled back.
-
The grant on the quote before you agree
Your quote shows the full price, the likely grant and your share, for mineral wool, and for hemp too if you’d like the natural option.
-
Blocked air bricks priced in from the start
If paving or a later step covers an air brick, a vent extender opens it up again, and that cost is already in the quote.
-
Partick sits close to our East Kilbride base
At 20 to 30 minutes away, it’s well inside our usual working area for surveys and fitting days.
-
Photos of the work under your floor
The crew photographs the insulation once it’s in and sends you the pictures, so you can see what the boards now hide.
What Underfloor Insulation Costs in Partick After the £1,500 Grant
Mineral wool under a standard floor comes to £1,400 to £2,500, depending on the floor area and how easy the gap is to work in.
- GrantUp to 75%, capped at £1,500, if you qualify
- LoanInterest-free, up to £500
- If your household qualifies, Home Energy Scotland covers up to 75% of the job to a £1,500 cap, leaving you £350 to £1,000 to pay.
- Take a £2,000 floor. 75% of that comes to exactly £1,500, so you’d pay £500. Above £2,000, the grant can’t rise any further.
- IndiTherm hemp is the natural option. It costs £3,000 to £5,000, which a full grant brings down to £1,500 to £3,500. It goes in from above with the boards up, between membranes and tape that stop draughts blowing through it.
- Home Energy Scotland decides every floor insulation grant application, and we supply the installer paperwork. Until it confirms, the grant on your quote is our estimate.
Whatever the floor grant comes to counts towards the £7,500 limit each home has across every measure claimed. For your own share, Home Energy Scotland offers an interest-free loan capped at £500 on underfloor work.
Three Guarantees on Every Partick Floor
Every floor is fitted to PAS 2030, the standard for installing insulation, by a company on the TrustMark register Home Energy Scotland requires.
What you get on every floor we insulate:
-
25-year workmanship guarantee
A 25-year workmanship guarantee on the fitting.
-
TrustMark and PAS 2030 certified
Audited work that meets the standards the grant requires.
-
No deposit
No deposit, so you pay nothing before fitting day.
-
Payment on 7-day terms
Payment within 7 days of completion, once your floor is finished.
Ask your own questions about underfloor insulation in Partick.
Not sure if your flat sits on timber or concrete? Walk round the outside of the building, look for small vents close to the ground and tell Calum what you find.
Underfloor Insulation in Partick: Your Questions Answered
The questions we hear most.
Between £1,400 and £2,500 for mineral wool. A household that qualifies for the grant pays £350 to £1,000. Natural hemp is £3,000 to £5,000 before the grant.
Book Your Free Survey ↓Up to 75%, capped at £1,500. An interest-free loan of up to £500 is also available. Eligibility is Home Energy Scotland’s call, and it pays only for work by TrustMark-registered installers.
Book Your Free Survey ↓Yes, if there’s a hatch and room to crawl underneath. If not, a few boards come up so the crew can work from above, and they go back down the same day. Whether you can insulate without lifting the floorboards comes down to the depth of the gap, which the survey measures.
Not while air keeps moving underneath. Open air bricks keep the joists dry, so the crew leaves every one clear and fits an extender to any that’s blocked.
Book Your Free Survey ↓Not with this job. The space under your boards is the ceiling of the flat below, so there’s no gap to fill. Underfloor insulation suits ground-floor and main-door flats over an open gap.
A standard floor is a one-day job, tidied before the crew leaves. A shallow or awkward gap can take longer, and you’ll hear that at the survey.
Book Your Free Survey ↓On a suspended timber floor, yes. Once the cold air under the boards can’t reach them, the floor stops pulling heat out of the room and the draughts at the skirting ease. The survey confirms you have that kind of floor before anything is quoted.
Yes, both. Each is a short drive from our East Kilbride base, and their older tenements often have the same timber ground floors.